RO Motor / Booster Pump Kaam Nahi Kar Raha? Karan, Testing Aur Repair

RO Motor / Booster Pump Kaam Nahi Kar Raha? Karan, Testing Aur Repair
RO Motor / Booster Pump Kaam Nahi Kar Raha? Karan, Testing Aur Repair
Short Answer: RO pump na chale to pehle 24V supply check karo — SMPS, LPS aur float switch. Supply sahi hai aur pump phir bhi na chale ya sirf hum kare, to pump motor ya pump head kharab hai. Pump chalta hai par pressure nahi banata to pump head weak hai.

Booster pump RO ka engine hai. Ye band ho jaye to membrane tak pressure nahi pahunchta aur RO pani banana band kar deta hai. Par har baar pump kharab nahi hota — kai baar problem supply me hoti hai.

Pump ke 3 hisse samjho

  • Motor: 24V DC motor jo ghoomti hai.
  • Pump head: Diaphragm wala hissa jo pani par pressure banata hai.
  • Wiring / connector: Supply laane wale taar.

Pump na chalne ke karan

1. Supply nahi pahunch rahi

SMPS kharab, LPS open, float switch atka ya connector dheela — in sab me pump tak 24V nahi pahunchta.

2. Motor jal gayi ya jam

Supply sahi hai phir bhi pump bilkul na ghoome ya sirf "hum" kare, to motor kharab hai.

3. Pump head weak

Motor chalti hai, awaaz aati hai, par pressure nahi banta — pump head ka diaphragm ya valve kharab hai.

Pump Problem: Kya Check Kare?

Multimeter se testing

  1. Plug lagao aur multimeter DC voltage par rakho.
  2. Pump ke connector par voltage naapo — lagbhag 24V aana chahiye.
  3. Voltage nahi to peeche jaao: float switch → LPS → SMPS.
  4. Voltage hai par pump nahi chalta = pump motor kharab.
💡 Pro Tip: Kai baar sirf LPS ki wajah se pump band hota hai. Test ke liye kuch second LPS ke dono taar jod kar dekho — pump chalne lage to LPS ya inlet pressure problem hai. Test ke baad connection wapas theek karo.
🔧 Ye sab practically seekhna hai?

RO Technician Course me har part, wiring, filter change aur repair — Hindi video lessons me, step by step. Mobile se ghar baithe seekho.

Abhi Enroll Karo — sirf ₹299 →

Pump awaaz kyun karta hai?

  • Mounting screw ya rubber pad dheela
  • Inlet me pani kam — pump sookha chal raha
  • Pump head purana ho gaya
ProblemSolutionAndaazan kharcha*
Sirf pump head weakPump head badlo₹700 – ₹1,500
Motor + head donoPura pump badlo₹1,200 – ₹2,500
Supply problemSMPS/LPS/connector₹100 – ₹700

* *Rate brand aur model ke hisaab se alag ho sakte hain.

⚠️ Dhyan dein: Naya pump lagate waqt SMPS ki current rating bhi check karo. Kamzor SMPS ke saath bada pump theek se nahi chalega.

FAQ

RO pump chalta hai par pani nahi banta, kya kare?

Solenoid valve, pre-filters aur pump head check karo. Sab theek ho to membrane choke ho sakta hai.

RO pump kitne volt ka hota hai?

Domestic RO me aam taur par 24V DC booster pump hota hai.

Pump head aur pump me kya fark hai?

Pump head pressure banane wala hissa hai, jabki pura pump motor + head milakar hota hai. Kai baar sirf head badalne se kaam ho jata hai.

RO pump kitne saal chalta hai?

Pani ki quality aur use par depend karta hai, aam taur par kai saal. Sookha chalne se jaldi kharab hota hai.

🛒
RO Purifier ya Spare Parts Wholesale Rate Me Chahiye?

Naya RO water purifier ho ya membrane, filter, booster pump, SMPS, solenoid valve jaise spare parts — aap inhe wholesale rate me rowholesaler.in se le sakte ho. Technician aur dukaandaron ke liye best option.

rowholesaler.in par dekho →

RO Technician banna hai? Aaj hi shuru karo

Padhne se zyada zaroori hai practical samajh. RO Courses par aap Hindi me, apne mobile se, apni speed se seekh sakte ho.

RO Technician Course
₹299
  • RO ke sabhi parts aur unka kaam
  • Theory + practical video lessons
  • Common problems ka diagnosis
  • Hindi me, mobile par
Enroll Karo →
Business ke liye best
Advance RO Technician Course
₹2,480
  • Theory + practical, detail me
  • Installation, service aur repair
  • Marketing ideas — customer kaise laye
  • Earning aur business ki guidance
Advance Course lo →

Leave a Reply